ENTRAcode+
Open your door with an individually programmable numeric code
ENTRAcode+ - the access control system with individually programmable numeric code. Doors can be opened without keys or access cards. The illuminated keypad does not leave you in the dark when you're entering your individual numeric code. The ENTRAcode+ is available in three versions tailored to your installation situation. The core module and the flush-mounted version are supplied with power via a mains connection. The surface-mounted version is battery-operated.
Product advantages
No key or access card necessary
ENTRAcode+ works with a numeric code of at least 4 and no more than 8 digits. You can set the code yourself.
Safety thanks to encrypted radio control system
The access system with encrypted SOMloq2 radio control system provides maximum security. The rolling code is encrypted with 128 bits. Backward compatibility of the transmitters to the Somloq Rollingcode radio control system is always available. Unlike wired systems, no short-circuiting or bridging is possible.
LED status displays
Integrated LEDs give you precise status messages using defined signals. For example, you are informed about low batteries or malfunctions in a timely manner.
Adjustable functions
The active time function allows you to send a radio command again by pressing any key, e. g. in order to stop a garage door. Time-delayed transmission can also be set.
Types
Flush-Mounted
Access control system for flush-mounting
- With its low installation height of 10 mm, it has an understated design that blends into the façade.
- Clear lines, a white housing and high-quality stainless steel trim for a timeless design
- Keypad with lighting
- Unlike wired systems, no short-circuiting or bridging possible
- Ideal for retrofitting thanks to radio technology
- For flush-mounted boxes in accordance with DIN 49073-1
- Flexible usage options, e. g. door operator, house door, lighting and alarm system can be controlled
# S11187-00001
Scope of delivery: ENTRAcode+ core module with code keypad in flush-mounting housing, faceplate in brushed stainless steel
A flush-mounted box is not included in the scope of delivery.
Designation | ENTRAcode+ Flush-Mounted |
Radio control system | SOMloq2 |
Radio commands | 1–5 |
Frequency | FM 868.8 MHz, FM 868.95 MHz |
Range | Approx. 25 m (depending on the surroundings) |
Temperature range | -25 °C to +65 °C |
Power supply | AC 12 V, DC 12–24 V |
Dimensions | 94 × 94 × 10 mm |
Protection class | IP65 |
Surface-mounted
Access control system for surface-mounting
- Clear lines, a white housing and high-quality stainless steel trim for a timeless design
- Battery-operated, no power supply connection or wiring necessary
- Keypad with lighting
- Ideal for retrofitting thanks to radio technology
- Unlike wired systems, no short-circuiting or bridging possible
- Flexible usage options, e. g. door operator, house door, lighting and alarm system can be controlled
# S11188-00001
Scope of delivery: ENTRAcode+ core module with code keypad in surface-mounting housing, faceplate in brushed stainless steel, 4 batteries
Designation | ENTRAcode+ Surface-Mounted |
Radio control system | SOMloq2 |
Radio commands | 1–5 |
Frequency | FM 868.8 MHz, FM 868.95 MHz |
Range | Approx. 25 m (depending on the surroundings) |
Temperature range | −20 °C to +55 °C |
Battery | 4x Mignon (AA), 1.5 V |
Dimensions | 46,5 × 130 × 37 mm |
Protection class | IP65 |
House doors
Access control system for house doors
- Encrypted and secure-transmission wireless connection between the code keypad in the door and radio receiver in the door profile
- Unlike wired systems, no short-circuiting or bridging possible
- System data is retained and the door remains securely locked in the event of a power failure.
- Flexible usage options in addition to the door, e.g. exterior lighting, alarm system and gate operator can be controlled
# S11192-00001
Scope of delivery: ENTRAcode+ core module with code keypad, faceplate in brushed stainless steel, radio receiver for door profiles
Designation | ENTRAcode+ for house doors |
Radio control system | SOMloq2 |
Radio commands | 1–5 |
Frequency | FM 868.8 MHz, FM 868.95 MHz |
Range | Approx. 25 m (depending on the surroundings) |
Temperature range | -25 °C to +65 °C |
Power supply | AC 12 V, DC 12–24 V |
Dimensions | Finger scanner: 87 × 47 × 26 mm Radio receiver: 120 × 24 × 37 mm |
Protection class | IP65 |
Sectional doors
Access control system for door panels
- For sectional doors with garage door operator SOMMER base+ or SOMMER pro+
- Cables are virtually invisible due to the travelling motor carriage
- Power is supplied via the motor carriage. No spiral cable is necessary.
- For sectional doors with four sections (panels), installation in the uppermost section
- Suitable for door panels from a thickness of 40 mm
- Unlike wired systems, no short-circuiting or bridging possible
- Faceplate in stainless steel or black coated stainless steel
- Special door fitting can also be used as a drill template
- Easy installation with the optional tool set # S11675-00001
# S11615-00001 – stainless steel
# S11615-00004 – stainless steel, black
Scope of delivery: ENTRAcode+ core module with code keypad, faceplate in brushed stainless steel or in black coated stainless steel, pre-assembled connecting cable, door bracket, cutting template
Designation | ENTRAcode+ Panel Set |
Radio control system | SOMloq2 |
Radio commands | 1–5 |
Frequency | FM 868.8 MHz, FM 868.95 MHz |
Range | Approx. 25 m (depending on the surroundings) |
Temperature range | -25 °C to +65 °C |
Power supply | AC 12 V, DC 12–24 V |
Dimensions | 87 × 47 × 26 mm |
Protection class | IP65 |
Universal
Access control system for universal application
- Encrypted and secure-transmission wireless connection between code keypad and radio receiver
- Unlike wired systems, no short-circuiting or bridging possible
- Flexible usage options, e.g. door operator, house door, lighting and alarm system can be controlled
- Ideal for use with electric openers, motor and automatic locks
# S11190-00001
Scope of delivery: ENTRAcode+ core module with code keypad, faceplate in brushed stainless steel
Designation | ENTRAcode+ Universal |
Radio control system | SOMloq2 |
Radio commands | 1–5 |
Frequency | FM 868.8 MHz, FM 868.95 MHz |
Range | Approx. 25 m (depending on the surroundings) |
Temperature range | -25 °C to +65 °C |
Power supply | AC 12 V, DC 12–24 V |
Dimensions | 87 × 47 × 26 mm |
Protection class | IP65 |